InstalSystem 5 版本发布说明:修订间差异
(→模块:) |
|||
| 第15行: | 第15行: | ||
|v4 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | |v4 =<!--Jest wersja -> zamienić na: "version2=" i uzupełnić link do sekcji RN danego produktu--> | ||
}} | }} | ||
==Information about changes== | |||
<!--In the absence of changes, standard text is published: "There were no significant functional changes in this release."--> | |||
===Version GOLD Rev. 6.1=== | |||
====Modules:==== | |||
'''InstalSystem basis and Package Manager''' | |||
* Added A0 and A1 formats to printout pages. | |||
* Improved AUTO and ORTO modes. | |||
'''Radiator sizing''' | |||
* Added possibility to display in radiator’s label setting of valves insert. | |||
* Allowed defining in project options default distance of radiator from wall. | |||
* Improved graphical presentation of radiators mounting items (so-called consoles) on plan views. | |||
'''Radiant loop systems''' | |||
* Added possibility to choose criterion of supply temperature optimization in radiant systems with correction of the algorithm's operation. | |||
* Improved algorithm of automatic division Heating/Cooling Zones into Heating/Cooling Areas. | |||
* Improved algorithm of automatic drawings of radiant heating/cooling loops. | |||
====Articles in HelpSystem:==== | |||
* [[How to include the drawing loop lenght in the calculations?]] | |||
* [[Preparation of building structure]] (actualized) | |||
* [[Appending drawings with radiant system loops]] (actualized) | |||
* [[Inserting plates in dry floor heating system]] | |||
===Version GOLD Rev. 5.1=== | |||
* There were no significant functional changes in this release. | |||
===Version GOLD Rev. 5.0=== | |||
====Modules:==== | |||
'''InstalSystem basis and Package Manager''' | |||
* Added dimension lines. | |||
'''Radiant loop systems''' | |||
* Improved the algorithm of automatic division of heating/cooling floor zone. | |||
* Improved presentation of RHC loop drawing on 3D view. | |||
* Extended functionality of pipe feed route to automatically fill the entire width of the stip with pipe feeds. | |||
====Articles in HelpSystem:==== | |||
* [[Automatically connect terminal units]] | |||
* [[Editing pipe feeds in a radiant system - Good practices and use cases]] | |||
* [[Software configuration]] (actualized) | |||
* [[Radiant heating systems - how to improve thermal and hydraulic results]] | |||
* [[Design of radiant heating floor and wall installation]] (actualized) | |||
* [[Design based on a project file from InstalSystem 4]] | |||
* [[Designing radiant (ceiling, wall) panel heating/cooling systems]] (actualized) | |||
* [[Designing radiant heating systems with pipe-runs as distribution system]] (actualized) | |||
===Version GOLD Rev. 4.0=== | |||
====Modules:==== | |||
'''Radiant loop systems''' | |||
* Improved the algorithm drawing the RHC loop. | |||
'''Radiant panel systems''' | |||
* Added ceiling panels zone - tool for automatic stacking of ceiling panels. | |||
====Articles in HelpSystem:==== | |||
* [[Import of building model from BIM compatible formats]] | |||
* [[Import underlay files]] (actualized) | |||
* [[Radiant steel ceiling panels]] (actualized) | |||
* [[Preparation of building structure - Creation of roofs with different construction]] | |||
* [[Preparation of building structure]] (actualized) | |||
===Version GOLD Rev. 2.2=== | |||
====Modules:==== | |||
'''InstalSystem basis and Package Manager''' | |||
* Added possibility to saved files read-only. | |||
* 3D view printout has been avaliable. | |||
====Articles in HelpSystem:==== | |||
* [[Calculation of design heat load of rooms]] | |||
* [[Designing radiant (ceiling, wall) panel heating/cooling systems]] (actualized) | |||
* [[How to eliminate: "Automatic division of H/C Zone not possible"]] | |||
* [[Presentation of the calculations result]] | |||
===Version GOLD Rev. 2.1=== | |||
* There were no significant functional changes in this release.. | |||
===Version GOLD Rev. 2.0=== | |||
====Initial scope of modules:==== | |||
* '''InstalSystem basis and Package Manager''' | |||
* '''Heat loss (thermal load)''' | |||
* '''Radiator sizing''' | |||
* '''Radiant loop systems''' | |||
* '''Radiant panel systems''' | |||
* '''Radiant loop dry systems''' | |||
* '''Heating systems''' | |||
* '''Radiant cooling systems''' | |||
* '''Interface gbXML (BIM)''' | |||
====Initial state of information materials==== | |||
* [[InstalSystem 5]] | |||
<!--* TUTAJ DODAĆ LINK DO STRONY WWW Z PRODUKTAMI INSTALSYSTEM 5--> | |||
<!--===Version BETA Rev. 2.0.B5=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced term licences as additional licensing option (available for selected packages) with mechanisms supporting term and renewal control (''Change license'' tab), | |||
* Introduced demo version (available for selected packages). | |||
* Added the ability to define window layouts. | |||
* The ''AUTO'' mode has been enhanced when inserting the ''Reference point''. | |||
* Organized tab ''Sources'' in the ''General data'' in order to improve the ergonomics and intuitive editing data. | |||
* The field ''Floor'' in the ''Storeys management'' obtained an additional ''AUTO'' status (the value is based on the typical floor heating thickness). | |||
* Added the ability to quickly locate and select the active elements windows for which diagnostic message shows. | |||
* Added the ability to enter text desctiprions and notes in the ''2D editor'' (icons: ''Text'' and ''Note'' in the group ''Labels and graphics''). | |||
===Version BETA Rev. 2.0.B4=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Put in order access to the most important diagnostic messages. | |||
* Diagnostics has been added to report errors during roof generating. | |||
* Added button which allows quick access to component style from the data table. | |||
* Improved ''Automatically connect terminal units'' function for quick removal of redundant pipe-runs. | |||
* Changed default unit (from ''m'' to ''mm'') for the storeys data field ''Floor''. | |||
* Predefined result project file names have been introduced. | |||
* Changed the name of the ''Upgrade'' button in Manager for ''Licence change'' button while preserving its original functionality. | |||
'''Heat loss (thermal load)''' | |||
* The format ''Heat losses data'' moved from the ''H&E'' window to the ''General Data'' window. | |||
'''Radiant heating - loop systems''' | |||
* Added the ability to define the default type of 3D valve in the mixer. | |||
* The default mixer size has been corrected. | |||
===Version BETA Rev. 2.0.B3=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Edit tabs in graphical editor got two new states of visibility: | |||
** ''Translucent when active'' - useful when analyzing the partition definitions and graphics partitions in 3D. | |||
** ''The only one visible when inactive'' - automatically inactivates other ranges, regardless of their own settings. | |||
'''Heat loss (thermal load)''' | |||
* Multi-storey rooms are recognized (equivalent to ''interconnected rooms'' in version 4). A multi-storey room is automatically created in the absence of a slab between rooms on adjacent floors when the slab does not cover the whole projection of the room or when the slab has an active opening in slab. | |||
* It is possible to select partition definitions as ''default for this type and dimensions'' also in the project browser tree, using the pop-up menu. | |||
* It is possible to specify the thickness for the partition definitions without layers (Partition with specified "U") so that they can also be assigned automatically. | |||
====Articles in HelpSystem:==== | |||
* [[Appending drawings with radiant system loops]] (actualized) | |||
* [[Technical specifications of InstalSystem 5 package]] (actualized) | |||
===Version BETA Rev. 2.0.B2=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Fixed walls connecting generated automatically by the partitions generator. | |||
* Fixed connecting fragments of the underlay in .pdf format. | |||
* Standardized the list of kinds and types of rooms. | |||
* Allowed quickly switching between worksheets in a graphical editor using the arrows next to the selection window of the worksheets. | |||
'''Radiant heating - loop systems''' | |||
* Moved window of control circuit settings to Thermal systems sources in the General Data. | |||
* Allowed to replace virtual temperature sources with graphic elements by ugins a special button in the control circuit settings in the General Data. | |||
===Version BETA Rev. 2.0.B1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced the ability to search elements in the Project browser based on a string of signs. | |||
* Allowed to insert dormers. | |||
====Articles in HelpSystem:==== | |||
* [[Designing heating systems with convective radiators]] | |||
* [[Designing of radiant heating installation on the basis of data from the Smart application]] | |||
* [[Heating/cooling zone]] | |||
* [[Using catalogs and catalogs data in the project]] | |||
===Version BETA 37 Rev. 0.0.B37=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved efficiency of the program in handling with complex projects, time of files upload and regeneration of the 3D view. | |||
'''Radiator sizing''' | |||
* Added the ability to search of radiators and valves placed on the radiators in the search window of elements in the project. | |||
'''Heat loss (thermal load)''' | |||
* Introduced heat loss (thermal load) module in accordance with standard EN 12831. | |||
====Articles in HelpSystem:==== | |||
* [[Preparation of building structure]] (actualized) | |||
* [[Smart application - Quick selection of system components]] (actualized) | |||
===Version BETA 35 Rev. 0.0.B35=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Raising the ergonomics of editing the roof by multiedit few vertices at the same time. | |||
* Merge and trim functions identify the premises in one operation. | |||
* Introduced new physical elements - arched Windows and doors. | |||
* Introduced new physical element - Opening in slab. | |||
* Improved support for facilities construction if the hole in the roof. | |||
* Introduced new feature - Building contour. | |||
* Introduced the interpretation of walls based on stroke building. | |||
* Introduced a new feature - Partitions generator. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] (actualized) | |||
* [[General data]] | |||
* [[Import files]] (actualized) | |||
* [[Manifold and accessories]] (actualized) | |||
* [[Preparation of building structure]] | |||
===Version BETA 34 Rev. 0.0.B34=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved import files created in InstalSystem 4 for automatic deletion of elements that are not supported in InstalSystem 5. | |||
* Improved ''Wall'' connection. | |||
* Integrated a full range of Construction processing operations. | |||
'''Radiator sizing''' | |||
* Expanded radiator sizing in ''Addition for thermostat'' and ''Addition for casing/chanel''. | |||
* Expanded operations on the elements ''Radiators'' about the possibility of ''Flip horizontal''. | |||
====Articles in HelpSystem:==== | |||
* [[Design of radiant heating/radiant cooling installation]] | |||
* [[Designing radiant (ceiling, wall) panel heating/cooling systems]] | |||
* [[Designing radiant heating systems with pipe-runs as distribution system]] | |||
* [[Radiant steel ceiling panels]] | |||
===Version BETA 33 Rev. 0.0.B33=== | |||
====Modules:==== | |||
'''Radiant heating - loop systems''' | |||
* Improved the data propagation from ''Room'' elements created with walls to the ''Heating/Cooling Wall Zone'' elements. | |||
'''Radiator sizing''' | |||
* Improved the data propagation from ''Room'' elements created with walls to the ''Radiator'' elements. | |||
===Version BETA 32 Rev. 0.0.B32=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced the ability of creating rooms due to other building structure's elements inserted in the project. | |||
* Introduced the ability of dividing roof into parts and added new functionality which allows to change ordinates of individual points at the roof's outline to model its real surface. | |||
* Introduced new physical element - roof window. | |||
* Introduced new physical element - recess. | |||
* Improved evaluating the location of the elements above the plane of the floor. | |||
* Increased the ergonomy of label editor. | |||
'''Radiator sizing''' | |||
* Introduced radiator sizing in basic scope. This functionality will be completed and developed in the next beta versions. | |||
====Articles in HelpSystem:==== | |||
* [[Design of radiant heating floor and wall installation]] | |||
===Version BETA 31 Rev. 0.0.B31=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced a new conception for wall element and the functionality of connecting walls. | |||
* Indroduced new physical element - the slab. | |||
* Indroduced new physical element - the roof. | |||
* Expanded function "Shadow of a storey" for possibility to declare shadows displayed for all stories below. | |||
'''Radiant heating - panel systems''' | |||
* Introduced possibility of calculating thermal output of ceiling/wall panels according to EN 1264 standard. | |||
====Articles in HelpSystem:==== | |||
* [[Release notes InstalSystem Smart5]] | |||
===Version BETA 30 Rev. 0.0.B30=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Allowed to control the content of diagnostic messages using the checkbox "Messages for selected components" on the list of filters in the diagnostics window. | |||
* Introduced the possibility to handle by the distribution system mail domains with the sign "-". | |||
'''Radiant heating - panel systems''' | |||
* Taken into account results for panels in the radiant heating general results. | |||
* Introduced the presentation of panels connection points on 3D view. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] (atualizado) | |||
* [[How to eliminate problems with the diagnostic message: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually"]] | |||
* [[Smart application - Quick selection of system components]] | |||
===Version BETA 29 Rev. 16.5.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Allowed handling of mail domains containing sign "-" by the licence distribution system. | |||
* Improved stability of the program during pasting complex installations. | |||
* Introduced the ability to display the storeys shadow above and below on 2D view. | |||
* For each element with snapping possibility added the ability to set in the AUTO mode a parameter which predetermine distance from the edge of another inserted element. | |||
'''Radiant heating - loop systems''' | |||
* Corrected a bug related to the manual connecting RHC loop directly to the manifold (without pipe-runs). | |||
'''Radiant heating - panel systems''' | |||
* Allowed the presentation of data in the printout of 'Manifold table' for panel systems installation. | |||
'''Radiant heating - dry systems''' | |||
* Introduced dry system to the neutral catalogue of radiant heating systems. | |||
====Articles in HelpSystem:==== | |||
* [[Installation, activation and update InstalSystem 5 package]] | |||
* [[Manifold and accessories]] | |||
* [[Project and application management]] | |||
===Version BETA 28 Rev. 16.4.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved the automatic snapping of pipe-runs for the ORTO mode. | |||
* Improved the function of rooms interpretation for files imported from '''[[InstalSystem 4]]''' package. | |||
* Introduced the ability to insert into the project construction elements: ''Wall'', ''Window'', ''Door'', ''Opening in wall''. | |||
'''Radiant heating - panel systems''' | |||
* Introduced the possibility to insert into the project element ''Ceiling false panel'' (panel with no connection). | |||
* Added the cooling result card for panel installation: ''General results cooling''. | |||
* Included elements: ''Wall panel'' and ''Ceiling panel'' in results card: ''General results heating''. | |||
===Version BETA 27 Rev. 16.3.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved function 'automatically connect terminal units'. | |||
* Made available the ability to configure the buttons to select a group of elements (SHIFT and CTRL). | |||
* Introduced possibility of selecting 'None' in the climatic data in case of lack of apropriate climatic data catalogue in the program. | |||
* Added the function of the graphic presentation of the route of flow from a given receiver to the source. | |||
* Added the function of the graphic presentation of routes flow from the source (manifold, source) to all receivers, which it supplies. | |||
'''Radiant heating - dry systems''' | |||
* Introduced handling underfloor panels which lead the pipes in dry systems of radiant heating. | |||
===Version BETA 26 Rev. 16.2.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved saving files in a network location. | |||
* Introduced the possibility to choose the source for which you want to appear the critical circuit. | |||
===Version BETA 25 Rev. 16.1.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added function that allows automatically connect terminal units. | |||
* Added possibility of quick creating rectangular room with sides parallel to the X, Y by drawing diagonal of the room. | |||
* The problem with sending Problem Report Form is eliminated. | |||
'''Radiant heating - panel systems''' | |||
* Added function that allows connect panels in series. | |||
* Introduced the possibility to design heating/cooling installations using ceiling/wall panels (including radiant steel ceiling panels).<br/>''Attention! Required upgrade to the configuration with the new module (InstalSystem Manager - tab "Upgrade"). | |||
====Articles in HelpSystem:==== | |||
* [[Connecting storeys with the "Stack" element]] | |||
* [[View navigation in the graphical editor]] | |||
* [[Combine base files]] | |||
===Version BETA 24 Rev. 15.12.1=== | |||
''Warning! For this version of the program the reinstallation is necessary.'' | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved stability and quality of the program. | |||
'''Radiant heating - loop systems''' | |||
* Added a message about the lack of possibility for editing automatically generated pipe feeds/RHC loops. | |||
* Standarized the content of data table for heating/cooling zones at various ranges of editing. | |||
* Introduced permanent visibility of the field ''Pipe laying pattern'' in the data table for heating/cooling zones. | |||
* Fixed an error that occurs while connecting pipe feeds route to the heating/cooling zone. | |||
====Articles in HelpSystem:==== | |||
* [[Export / print results and drawings]] | |||
* [[Software configuration]] (actualized) | |||
===Version BETA 23 Rev. 15.11.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Fixed the problem with sending the Problem report form. | |||
* Added icons for the .isproj files displayed in the InstalSystem Manager and in the Windows Explorer's window. | |||
* The scope of the displayed catalogues in the general data has been adapted to the available project scope for the package. | |||
'''Radiant heating - loop systems''' | |||
* Changed the designation of nodes in the grid which supports the manual drawing of the loop. | |||
* Added message box indicating the inability to remove the RHC loop. | |||
'''Heating network with balancing''' | |||
* Fixed the automatic sizing of manifolds' cabinets. | |||
* Improved the propagation of the default data for manifold cabinet. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] | |||
* [[How to make the program run faster]] | |||
* [[Installation with ceiling heating and cooling system in commercial building]] | |||
* [[Search components in the project]] | |||
===Version BETA 22 Rev. 15.10.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay. | |||
* Improved ORTO and AUTO modes. | |||
* Fixed the problem with sending error report form after crash of the program. | |||
* Improved overall stability and quality of the program by eliminating the reported errors. | |||
====Articles in HelpSystem:==== | |||
* [[Import files]] | |||
* [[Appending drawings with radiant system loops]] | |||
===Version BETA 21 Rev. 15.9.2=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Modified the way of importing base drawing files. | |||
* Added a ''Select components in rectangle'' function under the left mouse button. | |||
* Improved acting of ''ORTO'' mode when moving objects. | |||
* Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower. | |||
'''Radiant heating - loop systems''' | |||
* Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold. | |||
* Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects. | |||
'''Heating network with balancing''' | |||
* Added the possibility to use multi-circuit heating floor zone. | |||
* Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold. | |||
* Added the possibility to supply multi-circuit heating floor zone from several manifolds. | |||
* Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold. | |||
====Articles in HelpSystem:==== | |||
* [[Calculation of cooling capacity for radiant systems (floor, wall or ceiling)]] | |||
* [[How to calculate a file using a package configuration other than the one under which the file was created]] | |||
* [[Installation with underfloor and wall radiant heating system in single family building]] | |||
===Version BETA 16.1 Rev. 15.5.17=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added new tool to search and select items in the project. | |||
* Improved the import and export of bases. | |||
* Introduced the control of print range which based on the edition range and the elements' styles. | |||
* Introduced the possibility to highlight and select project's elements to which messages on the diagnostic list referred to. | |||
* Added the possibility to highlight on the worksheet elements forming the circuit of specified receptor from this worksheet. | |||
'''Radiant heating - loop systems''' | |||
* Improved the functionality of pipe feed automatic generation. | |||
====Articles in HelpSystem:==== | |||
* [[Software configuration]] | |||
===Version BETA 15.1 Rev. 15.4.21=== | |||
====Initial scope of modules:==== | |||
* '''Base module, including InstalSystem Manager''' | |||
* '''Radiant heating - loop systems''' | |||
* '''Cooling mode for radiant systems''' | |||
* '''Heating network with balancing''' | |||
* '''BIM Interface (gbXML)''' | |||
====Initial state of articles in HelpSystem==== | |||
* [[Technical specifications of InstalSystem 5 package]] | |||
* [[Introduction to the work with the package InstalSystem 5]]--> | |||
[[Category:InstalSystem 5]] | |||
[[Category:PRODUCT INFORMATION]] | |||
[[it:Informazioni sulle pubblicazioni InstalSystem 5]] | |||
[[pl:Informacje o publikacjach InstalSystem 5]] | |||
[[lt:InstalSystem 5 Pastabos apie versiją]] | |||
[[bg:Информация относно промени в InstalSystem 5]] | |||
[[zh-cn:InstalSystem 5 版本发布说明]] | |||
==有关更新的信息== | ==有关更新的信息== | ||
2018年1月29日 (一) 11:46的版本
| 产品 | InstalSystem 5 |
| 文章类型 | 产品信息 |
| 版本的最新内容 | IS 5.0 Beta Rev. 2.0.B1 |
Information about changes
Version GOLD Rev. 6.1
Modules:
InstalSystem basis and Package Manager
- Added A0 and A1 formats to printout pages.
- Improved AUTO and ORTO modes.
Radiator sizing
- Added possibility to display in radiator’s label setting of valves insert.
- Allowed defining in project options default distance of radiator from wall.
- Improved graphical presentation of radiators mounting items (so-called consoles) on plan views.
Radiant loop systems
- Added possibility to choose criterion of supply temperature optimization in radiant systems with correction of the algorithm's operation.
- Improved algorithm of automatic division Heating/Cooling Zones into Heating/Cooling Areas.
- Improved algorithm of automatic drawings of radiant heating/cooling loops.
Articles in HelpSystem:
- How to include the drawing loop lenght in the calculations?
- Preparation of building structure (actualized)
- Appending drawings with radiant system loops (actualized)
- Inserting plates in dry floor heating system
Version GOLD Rev. 5.1
- There were no significant functional changes in this release.
Version GOLD Rev. 5.0
Modules:
InstalSystem basis and Package Manager
- Added dimension lines.
Radiant loop systems
- Improved the algorithm of automatic division of heating/cooling floor zone.
- Improved presentation of RHC loop drawing on 3D view.
- Extended functionality of pipe feed route to automatically fill the entire width of the stip with pipe feeds.
Articles in HelpSystem:
- Automatically connect terminal units
- Editing pipe feeds in a radiant system - Good practices and use cases
- Software configuration (actualized)
- Radiant heating systems - how to improve thermal and hydraulic results
- Design of radiant heating floor and wall installation (actualized)
- Design based on a project file from InstalSystem 4
- Designing radiant (ceiling, wall) panel heating/cooling systems (actualized)
- Designing radiant heating systems with pipe-runs as distribution system (actualized)
Version GOLD Rev. 4.0
Modules:
Radiant loop systems
- Improved the algorithm drawing the RHC loop.
Radiant panel systems
- Added ceiling panels zone - tool for automatic stacking of ceiling panels.
Articles in HelpSystem:
- Import of building model from BIM compatible formats
- Import underlay files (actualized)
- Radiant steel ceiling panels (actualized)
- Preparation of building structure - Creation of roofs with different construction
- Preparation of building structure (actualized)
Version GOLD Rev. 2.2
Modules:
InstalSystem basis and Package Manager
- Added possibility to saved files read-only.
- 3D view printout has been avaliable.
Articles in HelpSystem:
- Calculation of design heat load of rooms
- Designing radiant (ceiling, wall) panel heating/cooling systems (actualized)
- How to eliminate: "Automatic division of H/C Zone not possible"
- Presentation of the calculations result
Version GOLD Rev. 2.1
- There were no significant functional changes in this release..
Version GOLD Rev. 2.0
Initial scope of modules:
- InstalSystem basis and Package Manager
- Heat loss (thermal load)
- Radiator sizing
- Radiant loop systems
- Radiant panel systems
- Radiant loop dry systems
- Heating systems
- Radiant cooling systems
- Interface gbXML (BIM)
Initial state of information materials
有关更新的信息
版本BETA Rev. 2.0.B5
模块:
基本模块,包括InstalSystem 管理器
- 引入了许可证期限作为额外的许可选项(针对所选择的软件包),并带有所支持的期限和续沿控制(许可号升级 按钮)
- 增加了定义窗口布置的能力
- 当插入参考点 时,增强了自动 捕捉模式
- 在一般参数 窗口中,重组了源 选项卡,提高了工效,编辑数据也更直观
- 在楼层管理 中的地面 字段内增加了自动 获取地面构造厚度值的状态(该值基于典型地面供暖的结构厚度)
- 添加了对所显示的诊断信息快速定位并选择活动部件所在的窗口的能力
- 在2D编辑器 中增加了输入文字描述和备注的能力(在标签和图形 选项卡中有文字 和注释 标签)
版本BETA Rev. 2.0.B4
模块:
基本模块
- 依次放入了最重要的诊断信息。
- 在屋顶生成期间的诊断信息添加到了错误报告中。
- 在参数表中添加了快速访问部件外观样式的按钮。
- 改进了自动连接末端装置的功能,可快速去除多余的管道。
- 将楼层参数表中地面的默认单位从m 变为了mm。
- 引入了预定义的结果项目文件名称。
- 将管理器中升级 的按钮名称改成了许可号升级,其功能未变。
热损失(热负荷)
- 将热负荷参数 从热负荷 窗口移到了一般参数 窗口。
辐射供热 - 盘管系统
- 添加了对混水装置自定义三通阀省缺型号的能力。
- 修改了混水装置的省缺尺寸。
版本BETA Rev. 2.0.B3
模块:
基本模块
- 在图形编辑器中增加了两个新的图形可视状态:
- 没激活时为半透明 - 当在3D视图中分析维护结构的定义以及图形时很有用。
- 当激活时是唯一可见的 - 这将自动关闭其它图层,无论它们的设置如何。
热损失(热负荷)
- 识别多层建筑的房间(相当于V4版中的互连的房间)。一多层建筑的房间在缺少相邻楼层房间之间的楼板的情况下,如楼板没有覆盖整个房间的投影或楼板开洞时也可创建房间。
- 在项目浏览器的树状图中,使用下拉式菜单可将隔断定义选为对此种类型和尺寸的省缺值。
- 对于没有各层定义的围护结构(使用指定"U"值的维护结构)可指定厚度以便自动给它们赋值。
在帮助系统中的相关文章:
版本BETA Rev. 2.0.B2
模块:
基本模块
- 修改了由隔断生成器自动生成的墙的连接。
- 修改了PDF格式底图片段的连接。
- 标准化了房间种类和形式清单。
- 允许在图形编辑器中使用屏幕左下角的工作表选择窗口左侧的箭头快速在工作表间进行切换。
辐射供热 - 盘管系统
- 将控制回路设置窗口移到了一般参数 -热力系统 -源 下。
- 在一般参数的控制回路设置中允许使用一特殊按钮将虚拟的源用图中的源来代替。
版本 BETA Rev. 2.0.B1
模块:
基本模块
- 在项目浏览器中引入了基于字符串搜索部件的能力。
- 允许插入天窗。
在帮助系统中的相关文章:
版本 BETA 37 Rev. 0.0.B37
模块:
基本模块
- 提高了处理复杂项目的效率、缩短了文件上传的时间和3D视图的再生时间。
散热器计算
- 增加了在项目浏览器窗口中搜索散热器和散热器阀门的能力。
热损失(热负荷)
- 增加了基于EN12831标准计算热损失(热负荷)的模块(适用于高配版本)。
在帮助系统中的文章:
版本 BETA 35 Rev. 0.0.B35
模块:
基本模块
- 通过同时多点编辑几个顶点,提高了屋顶编辑的功效。
- 一次操作即可完成建筑物的识别、合并和修剪功能。
- 引入了新的物理部件 - 拱形门窗。
- 引入了新的物理部件 - 楼板开口(挑空)。
- 改善了对屋顶开孔结构的支持。
- 引入了通风井建筑墙的编译。
- 引入了一新功能 - 建筑轮廓。
- 引入了一新功能 - 隔断生成器。
在本帮助系统中的文章:
版本 BETA 34 Rev. 0.0.B34
模块:
基本模块,包括 InstalSystem 管理器
- 改进了导入Instalsystem 4所创建的文件,自动删除InstalSystem 5中不支持的元素。
- 改进了墙 的连接。
- 在整个范围内整合了建筑 的处理操作。
散热器设计计算
- 增加了散热器因考虑温控器,增加 和考虑外罩或位于沟槽内,增加 尺寸的选项。
- 扩展了对于散热器 部件有关水平翻转 操作的可能性。
在帮助系统中的文章:
版本 BETA 33 Rev. 0.0.B33
模块:
辐射供热 - 盘管系统
- 改进了数据从使用墙所创建的房间 部件到供热/供冷墙区 部件的传递。
散热器设计计算
- 改进了数据从使用墙所创建的房间 部件到散热器 部件的传递。
版本 BETA 32 Rev. 0.0.B32
模块:
基本模块,包括InstalSystem 管理器
- 引入了由项目中所插入的其它建筑结构部件而创建房间的能力。
- 引入了将屋顶分割为几部分并增加了允许修改屋顶外轮廓各点坐标的能力,从而使所创建的模型与真实情况相符。
- 引入了新的物理部件 - 天窗。
- 引入了新的物理部件 - 凹槽。
- 改进了对地板上方部件位置的评估。
- 增加了标签编辑器的工效.
散热器设计计算
- 将散热器的设计计算引入到基本范围。该功能将在下一版本中开发和完成。
在帮助系统中的文件:
版本 BETA 31 Rev. 0.0.B31
模块:
基本模块,包括InstalSystem 管理器
- 引入了墙部件的新概念和墙连接的功能。
- 引入了新的物理元件 - 楼板。
- 引入了新的物理元件 - 屋顶。
- 扩展了“阴影显示某一层”的功能,可声明将所有下方或上方的楼层均阴影显示的可能性。
辐射采暖 - 辐射板系统
- 引进了基于EN 1264标准对辐射吊顶板/墙面辐射板计算冷热输出的可能性。
在帮助系统中的文件:
版本 BETA 30 Rev. 0.0.B30
模块:
基本模块,包括 InstalSystem 管理器
- 可在诊断窗口的过滤器清单中使用“选定部件的信息”的复选框控制诊断信息的内容。
- 引入了使用符号 "-" 处理分发系统邮件域的可能性。
辐射供热 - 辐射板系统
- 在辐射供暖一般结果中考虑了辐射板的结果。
- 在3D视图中引入了辐射板连接点的展示。
在帮助系统中的文章:
版本 BETA 29 Rev. 16.5.1
模块:
基本模块,包括InstalSystem 管理器
- 许可证分销系统允许处理含有符号“-”的邮件域。
- 在粘贴复杂部件时提高了程序的稳定性。
- 在2D编辑器中引入了上/下楼层阴影显示的能力。
- 对于带有捕捉能力的每个部件,增加了在自动模式下设置参数来预定义距下一个要插入的部件边部的距离。
辐射供暖 - 盘管系统
- 修正了一个与手动将供热供冷回路直接连接到分集水器(无管路)上的相关错误。
辐射供热 - 辐射板系统
- 允许在分集水器表的打印输出中显示辐射板系统的参数。
辐射供热 - 干式系统
- 将干式系统引入到了基本地面辐射供暖系统中。
在帮助系统中的文章:
版本 BETA 28 Rev. 16.4.1
模块:
基本模块,包括InstalSystem 管理器
- 改进了定向线模式下管道的自动捕捉。
- 改进了对于InstalSystem 4 软件包所导入文件中的房间的编译功能
- 引入了将墙、窗、门、墙洞 插入到项目建筑部件中的能力
辐射供热供冷 - 辐射板系统
- 引入了插入项目部件假辐射吊顶板(吊顶板内无管材)的能力。
- 为辐射板装置的供冷结果添加了:一般供冷结果。
- 在结果窗口的一般供热结果 中包括的部件有:墙面辐射板 和顶面辐射板。
版本 BETA 27 Rev. 16.3.1
模块:
基本模块,包括InstalSystem管理器
- 改进了'自动连接末端装置'的功能。
- 增加了通过配置按钮选择一组部件的能力(SHIFT 和 CTRL)。
- 引入了若在程序中缺少适宜的气候数据目录的情况下,在一般参数的气象参数设置中选择'无'的可能性。
- 增加从指定末端到源的水流路径图形表示的功能。
- 增加了从源(分集水器、源)到所有末端水流路径图形表示的功能。
辐射供热 - 干式系统
- 引入了干式辐射系统中管材在预制沟槽保温板内的走向的处理。
版本 BETA 26 Rev. 16.2.1
模块:
基本模块,包括InstalSystem管理器
- 改进了在网络位置中文件的保存。
- 引入了选择要显示关键回路的源的可能性。
版本 BETA 25 Rev. 16.1.1
模块:
基本模块,包括InstalSystem管理器
- 新增功能,允许自动连接末端装置。
- 增加了对于房间两侧与X,Y轴平行的房间,通过绘制房间的对角线快速创建矩形房间的可能性。
- 发送问题报告表时出现的问题已消除。
辐射供热供冷 - 辐射板系统
- 增加了允许串联连接辐射板的功能。
- 引入了使用辐射吊顶板/墙面辐射板(包括钢制辐射吊顶板)设计供热/供冷系统的可能性。
注意! 需升级到带有新的模块的配置(InstalSystem 管理器 - 按钮"升级")。
在帮助系统中的文章:
版本 BETA 24 Rev. 15.12.1
警告! 对于此程序的版本需重新安装。
模块:
基本模块,包括InstalSystem管理器
- 改进了程序的稳定性和质量。
辐射供热 - 盘管系统
- 增加了关于不太可能自动生成引线管/辐射盘管的诊断信息。
- 对在不同编辑范围内的供热/供冷区,标准化了参数表的内容。
- 增加了对供热/供冷区参数表中的铺管方式 的永久显示。
- 修正了一个当连接引线管路径到供热/供冷区时出现的错误。
在帮助系统中文章:
版本 BETA 23 Rev. 15.11.1
模块:
基本模块,包括InstalSystem管理器
- 解决了发送问题报告时出现的问题。
- 添加了在InstalSystem 管理器和在Windows资源管理器窗口中显示.isproj文件的图标。
- 在一般参数中所显示的目录范围已调节到该软件包可用的项目范围。
辐射供热 - 盘管系统
- 更改了网格中对节点的指定,它可帮助手动绘制盘管图。
- 添加了指示无法删除供热/供冷回路的信息框。
供热管网的水力平衡
- 修正了分集水器箱的自动尺寸选型。
- 改进了分集水器箱省缺数据的传递。
在帮助系统中的文章:
版本 BETA 22 Rev. 15.10.1
模块:
基本模块,包括InstalSystem管理器
- 增加了绘图水平和垂直标尺,以帮助验证所导入底图的比例。
- 增加了定向线和自动模式。
- 解决了程序崩溃后发送错误报告时的问题。
- 改进了对报告错误消除时程序的整体稳定性和质量。
在帮助系统中文章:
版本 BETA 21 Rev. 15.9.2
模块:
基本模块,包括InstalSystem 管理器
- 修改了导入基本绘图文件的方法。
- 增加了按鼠标左键“选择矩形框中的部件”的功能。
- 改进了当移动目标时定向线 模式的作用。
- 加速了新创建的或再次保存的文件的加载速度,因为先前版本所创建的文件加载可能较慢。
辐射供热 - 盘管系统
- 添加几个辐射供暖供冷回路并联连接到分集水器一个共用的供回管路的可能性。
- 引入了对连接到不带内置平衡阀的分集水器上的辐射供暖供冷回路水力平衡的诊断功能,并增加了在管道上增加阀门来平衡这些对象的可能性。
供热管路的水力平衡
- 增加了地面供热区使用多回路的可能性。
- 引入了在不用分集水器的系统中对辐射供热供冷区回路的平衡诊断
- 对辐射供热区增加了多个分集水器供应多个回路的可能性。
- 引入了从虚拟的或图形的源而不用分集水器直接为供热/供冷区提供冷或热的可能性。
在帮助系统中的文章:
版本 BETA 16.1 Rev. 15.5.17
模块:
基本模块,包括InstalSystem 管理器
- 添加了在项目中新的搜索和选择部件的工具。
- 改进了底图的导入和输出。
- 引入了基于编辑范围和部件样式的打印范围控制。
- 引入了在诊断列表中对所提到的信息所指的部件进行选择并高亮显示项目部件的可能性。
- 增加了在工作表上高亮显示本工作表中形成指定末端回路部件的可能性。
辐射供暖 - 盘管系统
- 改进了引线管自动生成的功能。
在帮助系统中的文章:
版本 BETA 15.1 Rev. 15.4.21
最初的模块范围:
- 基本模块,包括 InstalSystem 管理器
- 辐射供暖 - 盘管系统
- 辐射系统的供冷模式
- 带水力平衡计算的供热管网
- BIM 界面(gbXML)