如何提高辐射供热系统的热工和水力性能:修订间差异

来自HelpSystem
跳转到导航 跳转到搜索
第11行: 第11行:
* '''房间''<IS_TS id=strOkladzina/>'' 的选择''' - 将影响辐射面供热的效率和辐射面温度分布的均匀性。<br> [[File:Material-of-covering.png|1200px|left|thumb|5. ''<IS_TS id=strOkladzina/>'']]<br clear="all"/> {{Info}} [[供热/供冷区#修改铺装构造参数|修改铺装构造参数]]<br>
* '''房间''<IS_TS id=strOkladzina/>'' 的选择''' - 将影响辐射面供热的效率和辐射面温度分布的均匀性。<br> [[File:Material-of-covering.png|1200px|left|thumb|5. ''<IS_TS id=strOkladzina/>'']]<br clear="all"/> {{Info}} [[供热/供冷区#修改铺装构造参数|修改铺装构造参数]]<br>


===PARAMETERS THAT CAN BE SET/ADJUSTED IN COMPLETED SYSTEM===
===在一套完整的系统中可设置/调整的参数===
* '''Supply temperature, if a system with adjustable temperature is used (e.g. gas-fired water heater with a mixer or a mixing pump set)'''<br>[[File:Supply-temperature-optimize-imposing.png|1200px|left|thumb|6. Supply temperature]]<br clear="all"/>{{Info}} [http://en.help.instalsoft.com/Design_of_radiant_heating_floor_and_wall_installation#Modifying_system_parameters_to_adapt_attained_output_to_required_output Modifying system parameters to adapt attained output to required output]<br>
* '''供水温度,如果系统的供水温度是可调的(如带有混水装置或混合泵站的燃气锅炉)'''<br>[[File:Supply-temperature-optimize-imposing.png|1200px|left|thumb|6. 供水温度]]<br clear="all"/>{{Info}} [地面和墙面辐射供热系统的设计#修改系统参数以使所计算的输出达到所要求的值|修改系统参数以使所计算的输出达到所要求的值]]<br>
* '''Maximum flow rate in floor heating loops''' - possible by adjusting ''<IS_TS id=stringRTMinSW/>'', ''<IS_TS id=stringRTMaxSW/>'', ''<IS_TS id=stringRTMinSB/>'' and ''<IS_TS id=stringRTMaxSB/>''  or by specifying ''<IS_TS id=strDeltaThetaLong/>''.<br>[[File:Maximum-flow-rate-in-heating-circuit.png|1200px|left|thumb|7. Parameters that have effect on maximum flow rate in floor heating loops]]<br clear="all"/>  {{Info}} [http://en.help.instalsoft.com/Heating/cooling_zone#Changing_operating_parameters Changing operating parameters]<br>
* '''Maximum flow rate in floor heating loops''' - possible by adjusting ''<IS_TS id=stringRTMinSW/>'', ''<IS_TS id=stringRTMaxSW/>'', ''<IS_TS id=stringRTMinSB/>'' and ''<IS_TS id=stringRTMaxSB/>''  or by specifying ''<IS_TS id=strDeltaThetaLong/>''.<br>[[File:Maximum-flow-rate-in-heating-circuit.png|1200px|left|thumb|7. 对地面辐射供热回路最大流量影响的参数]]<br clear="all"/>  {{Info}} [http://en.help.instalsoft.com/Heating/cooling_zone#Changing_operating_parameters Changing operating parameters]<br>


[[bg: Лъчисти отоплителни системи - как да подобрите топлинни и хидравлични резултати?]]
[[bg: Лъчисти отоплителни системи - как да подобрите топлинни и хидравлични резултати?]]
第19行: 第19行:


[[Category:InstalSystem 5]]
[[Category:InstalSystem 5]]
[[Category:TYPICAL PROBLEM]]
[[Category:典型问题]]

2017年12月10日 (日) 08:09的版本

问题说明

通过调整辐射供暖系统的结构和运行参数来改善热工和水力性能。
更多信息,见: 地面和墙面辐射供热系统的设计

解决方案

在设计辐射系统和确定辐射面的结构时应考虑的参数

  • 辐射末端的布置和尺寸 - 地面供热/供冷区 的面积越大,供水温度可越低。
    1. 地面供热/供冷区 的尺寸


    更多信息,见: 供热/供冷区
  • 当使用热泵作为热源时,其可提供的最高供水温度
  • 最大回路长度 - 将影响水流阻力和分集水器的规格,从而影响后期的运行费用和前期的初投资。
    2. 最大长度

  • 允许的管间距 - -将影响辐射供热表面的平均温度。
    3. 管间距

  • 辐射供热面下的绝热层厚度 - 将影响辐射供热的热损失(向建筑之外)
    4. 绝热层

  • 房间装饰层 的选择 - 将影响辐射面供热的效率和辐射面温度分布的均匀性。
    5. 装饰层

    更多信息,见: 修改铺装构造参数

在一套完整的系统中可设置/调整的参数

  • 供水温度,如果系统的供水温度是可调的(如带有混水装置或混合泵站的燃气锅炉)
    6. 供水温度

    更多信息,见: [地面和墙面辐射供热系统的设计#修改系统参数以使所计算的输出达到所要求的值|修改系统参数以使所计算的输出达到所要求的值]]
  • Maximum flow rate in floor heating loops - possible by adjusting Δθ 最小 内区, Δθ 最大 内区, Δθ 最小 外区 and Δθ 最大 外区 or by specifying 供回水温差.
    7. 对地面辐射供热回路最大流量影响的参数

    更多信息,见: Changing operating parameters