==Problem description==
<!--case 183902="-->
Thermal and hydraulic results improvement by adjusting structural and operating parameters of a radiant system heater.<br> {{Info}} [http://en.help.instalsoft.com/Design_of_radiant_heating_floor_and_wall_installation Design of radiant heating floor and wall installation]<br>
<IS_HELP id="HS99"/>
==Solution==
{{Article table
===PARAMETERS TAKEN INTO ACCOUNT WHEN DESIGNING A SYSTEM AND CONSTRUCTING===
|commercial_product1=InstalSystem 5
* '''Arrangement and size of radiant heaters''' - larger surface area of a ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' enables lowering supply temperature.<br>  [[File:Occupied-area-by-heat-zone.png|1200px|left|thumb|1. Size of ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'']]<br clear="all"/> <br>{{Info}} [[Heating/cooling_zone]]
|p2                =
* '''Maximum attainable supply temperature when heat pump is the source.'''<br>  
|p3                =
* '''Maximum loop length'''  - has effect on flow resistance and manifold size, and thereby also on operating and capital costs.<br> [[File:Max-Coil-Lenght-of-single-circuits.png|1200px|left|thumb|2.''<IS_TS id=strMaxDlugoscPetliSymbol/>'']]<br clear="all"/>
|p4                =
* '''Perimissible pipe spacing''' - has effect on mean surface temperature of radiant heater.<br> [[File:Pipes-spacing.png|1200px|left|thumb|3. Pipe spacing]]<br clear="all"/>
|category1          =InstalSystem 5#Typical problems
* '''Insulation thickness under radiant heater''' - has effect on ''<IS_TS id=sSumaStratyOPNaZwenatrz/>''.<br> [[File:Insulation-layers-thickness.png|1200px|left|thumb|4. Insulation layer]]<br clear="all"/>
|category_name1    =提示和技巧
* '''Selection of proper ''<IS_TS id=strOkladzina/>'' in rooms''' - has effect on radiant heater efficiency and on uniform temperature distribution on heater surface.<br> [[File:Material-of-covering.png|1200px|left|thumb|5.''<IS_TS id=strOkladzina/>'']]<br clear="all"/> {{Info}} [http://en.help.instalsoft.com/Heating/cooling_zone#Changing_structural_parameters Changing structural parameters]<br>
|c2                =
===PARAMETERS THAT CAN BE SET/ADJUSTED IN COMPLETED SYSTEM===
|category_name2    =
* '''Supply temperature, if a system with adjustable temperature is used (e.g. gas-fired water heater with a mixer or a mixing pump set)'''<br>[[File:Supply-temperature-optimize-imposing.png|1200px|left|thumb|6. Supply temperature]]<br clear="all"/>{{Info}} [http://en.help.instalsoft.com/Design_of_radiant_heating_floor_and_wall_installation#Modifying_system_parameters_to_adapt_attained_output_to_required_output Modifying system parameters to adapt attained output to required output]<br>
|c3                =
* '''Maximum flow rate in floor heating loops''' - possible by adjusting ''<IS_TS id=stringRTMinSW/>'', ''<IS_TS id=stringRTMaxSW/>'', ''<IS_TS id=stringRTMinSB/>'' and ''<IS_TS id=stringRTMaxSB/>''  or by specifying ''<IS_TS id=strDeltaThetaLong/>''.<br>[[File:Maximum-flow-rate-in-heating-circuit.png|1200px|left|thumb|7. Parameters that have effect on maximum flow rate in floor heating loops]]<br clear="all"/>  {{Info}} [http://en.help.instalsoft.com/Heating/cooling_zone#Changing_operating_parameters Changing operating parameters]<br>
|category_name3    =
|version1          =[[Release notes InstalSystem 5#Version BETA 22 Rev. 15.10.2|IS 5.0 Beta 3.B1]]
|v2                =
|v3                =
|v4                =
}}
 
==问题说明==
通过调整辐射供暖系统的结构和运行参数来改善热工和水力性能。<br> {{info}} [[地面和墙面辐射供热系统的设计|地面和墙面辐射供热系统的设计]]<br>
 
==解决方案==
===在设计辐射系统和确定辐射面的结构时应考虑的参数===
* '''辐射末端的布置和尺寸''' - ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' 的面积越大,供水温度可越低。<br>  [[File:供热区与墙的距离.png|1200px|left|thumb|1. ''<IS_TS id=iNameOPStrefaPodlogGrzejnych/>'' 的尺寸]]<br clear="all"/> <br>{{Info}} [[供热/供冷区]]
* '''当使用热泵作为热源时,其可提供的最高供水温度'''<br>  
* '''最大回路长度'''  - 将影响水流阻力和分集水器的规格,从而影响后期的运行费用和前期的初投资。<br> [[File:最大回路长度.png|1200px|left|thumb|2. ''<IS_TS id=strMaxDlugoscPetliSymbol/>'']]<br clear="all"/>
* '''允许的管间距''' - -将影响辐射供热表面的平均温度。<br> [[File:管间距.png|1200px|left|thumb|3. 管间距]]<br clear="all"/>
* '''辐射供热面下的绝热层厚度''' - 将影响''<IS_TS id=sSumaStratyOPNaZwenatrz/>'' <br> [[File:构造层厚度.png|1200px|left|thumb|4. 绝热层]]<br clear="all"/>
* '''房间''<IS_TS id=strOkladzina/>'' 的选择''' - 将影响辐射面供热的效率和辐射面温度分布的均匀性。<br> [[File:装饰面层的影响.png|1200px|left|thumb|5. ''<IS_TS id=strOkladzina/>'']]<br clear="all"/> {{Info}} [[供热/供冷区#修改铺装构造参数|修改铺装构造参数]]<br>
 
===在一套完整的系统中可设置/调整的参数===
* '''供水温度,如果系统的供水温度是可调的(如带有混水装置或混合泵站的燃气锅炉)'''<br>[[File:人为设定供水温度.png|1200px|left|thumb|6. 供水温度]]<br clear="all"/>{{Info}} [[地面和墙面辐射供热系统的设计#修改系统参数以使所计算的输出达到所要求的值|修改系统参数以使所计算的输出达到所要求的值]]<br>
* '''地面辐射供热回路中的的最大流量''' - 其调节可通过如下参数的调节来实现:''<IS_TS id=stringRTMinSW/>'', ''<IS_TS id=stringRTMaxSW/>'', ''<IS_TS id=stringRTMinSB/>'' ''<IS_TS id=stringRTMaxSB/>''  或指定''<IS_TS id=strDeltaThetaLong/>'' <br>[[File:交互式计算2.png|1200px|left|thumb|7. 对地面辐射供热回路最大流量影响的参数]]<br clear="all"/>  {{Info}} [[供热/供冷区#修改运行参数|修改运行参数]]<br>


[[bg: Лъчисти отоплителни системи - как да подобрите топлинни и хидравлични резултати?]]
[[pl: Ogrzewanie płaszczyznowe - sposoby poprawy wyników cieplnych i hydraulicznych]]


[[Category:InstalSystem 5]]
[[Category:InstalSystem 5]]
[[Category:TYPICAL PROBLEM]]
[[Category:提示和技巧]]
 
<!-- Do not write text below this tag -->
<br class="iwlinks"/>[[pl:Ogrzewanie płaszczyznowe - sposoby poprawy wyników cieplnych i hydraulicznych|Ogrzewanie płaszczyznowe - sposoby poprawy wyników cieplnych i hydraulicznych]][[en:Radiant heating systems - how to improve thermal and hydraulic results|Radiant heating systems - how to improve thermal and hydraulic results]]

2026年6月12日 (五) 23:15的最新版本


产品 InstalSystem 5
文章类型 提示和技巧
版本的最新内容 IS 5.0 Beta 3.B1


问题说明

通过调整辐射供暖系统的结构和运行参数来改善热工和水力性能。
更多信息,见: 地面和墙面辐射供热系统的设计

解决方案

在设计辐射系统和确定辐射面的结构时应考虑的参数

  • 辐射末端的布置和尺寸 - 地面供热/供冷区 的面积越大,供水温度可越低。
    1. 地面供热/供冷区 的尺寸


    更多信息,见: 供热/供冷区
  • 当使用热泵作为热源时,其可提供的最高供水温度
  • 最大回路长度 - 将影响水流阻力和分集水器的规格,从而影响后期的运行费用和前期的初投资。
    2. 最大长度

  • 允许的管间距 - -将影响辐射供热表面的平均温度。
    3. 管间距

  • 辐射供热面下的绝热层厚度 - 将影响辐射供热的热损失(向建筑之外)
    4. 绝热层

  • 房间装饰层 的选择 - 将影响辐射面供热的效率和辐射面温度分布的均匀性。
    5. 装饰层

    更多信息,见: 修改铺装构造参数

在一套完整的系统中可设置/调整的参数

  • 供水温度,如果系统的供水温度是可调的(如带有混水装置或混合泵站的燃气锅炉)
    6. 供水温度

    更多信息,见: 修改系统参数以使所计算的输出达到所要求的值
  • 地面辐射供热回路中的的最大流量 - 其调节可通过如下参数的调节来实现:Δθ 最小 内区, Δθ 最大 内区, Δθ 最小 外区Δθ 最大 外区 或指定供回水温差
    7. 对地面辐射供热回路最大流量影响的参数

    更多信息,见: 修改运行参数