Description

Design of a heating system, where heating floors are supplied directly from a high-parameter network may be prepared with InstalSystem 5 using the 地面供热/供冷区 component of the type:

  • 带有回水温度限制器
  • 带有回水温度限制器,来自散热器回水.

The 地面供热/供冷区 types named above are not divided automatically and consist of only one 供热/供冷面, that is one loop.

Location in the program

  • 地面 icons are available in the 2D Editor window on the 主工具 bar, section 辐射 with the 地面/墙面辐射 editing scope enabled.
    1. 供热/供冷区.

  • The type of the used 供热/供冷区 component can be selected in the 参数表 window, 供热/供冷区类型 field.
    2. 供热/供冷区: 带有回水温度限制器 and 带有回水温度限制器,来自散热器回水.

Example of use

Editing and setting the parameters

Inserting a component and selecting the functional type

Operating parameters

Structural parameters

Peripheral zones

Calculations

  • For the 地面供热/供冷区 带有回水温度限制器 and 带有回水温度限制器,来自散热器回水 components it is possible to change the determined value of 管间距 in the 交互式辐射系统计算 window.
    更多信息,见: Interactive calculations of radiant systems.

Heating/cooling floor zone with return temperature limiter

  • The 地面供热/供冷区 带有回水温度限制器 component should be connected by means of 管路 components to a high-parameter central heating system, supplying the 散热器 components and other 对流 units, connected to a used for 供热. On the return pipe-run of the 地面供热/供冷区 a 阀门 of the Return temperature limiter type should be installed.

  • For the 地面供热/供冷区 带有回水温度限制器, the enabled option 未绘制图形连接时,创建假想的连接 in the 假想的辐射系统连接 tab in the 一般参数 window is ignored.

Heating/cooling floor zone with return temperature limiter fed from radiator return

  • The 地面供热/供冷区 带有回水温度限制器,来自散热器回水 component should be connected to a high-parameter central heating network, supplying the 散热器 components and other 对流 units, connected to a used for 供热 in the following way:
    • for the 地面供热/供冷区 - using a 管路 of the 串联连接 type connected to the return line of a 散热器.
      Attention! 管路 of the 串联连接 type must run outside of the 地面供热/供冷区 area and must be connected to its edge from the outside. In most systems the 散热器 is positioned directly above the 地面供热/供冷区 and the simplest connection "from the inside of the room" is not handled by the program as yet.
    • - using a 管路 of the type, by connecting it directly to the return line from the radiators and other convection units. The return pipe-run from the 地面供热/供冷区 should be provided with a 阀门 of the Return temperature limiter type.

  • For the 地面供热/供冷区 带有回水温度限制器,来自散热器回水' the enabled option 未绘制图形连接时,创建假想的连接 in the 假想的辐射系统连接 tab in the 一般参数 window is ignored.