Presentation of data in the heating/cooling zone build-up editor
The 地面供暖/供冷构造 \ 墙面供热/供冷构造 \ 天花板供热/供冷构造 field presents overall thickness of the heating/cooling zone as well as overall thermal resistance.
Having opened the editor, the user gains access to particular data, on the basis of which overall values are calculated:
Overal thickness of heating/cooling zone layers. 3. 层的厚度
Thermal resistance of particular layers of a given heating/cooling zone along with structural partition thermal resistance. 4. 层的热阻
5. 总构造厚度 i 各层热阻
After data modification in the editor window, it is necessary to recalculate the project to update all values.
Heating/Cooling zone build-up edition
表面装饰层
6. 表面装饰层
默认的表面装饰层 originates from 一般参数 for 房间类型 elements. 7. 默认的表面装饰层
表面装饰层 may be changed for each 供热/供冷区 element. 8. 表面装饰层
砂浆/石膏层总厚度
9. 砂浆/石膏层总厚度
砂浆/石膏层总厚度, in case of the 自动 setting, may change according to the 地面最大工作载荷 value (), within limits allowed by the producer. The user may change thickness, also in the limits allowed by the system producer, while taking into consideration all other system data. 管顶上方回填层/石膏层厚度管顶以上厚度 is always calculated automatically by the program, and it cannot be changed manually.
系统构造板
10. 系统构造板
The user may change the structural panel if:
there are more structural panels than one for a given fastening method. 11. 系统构造板- choose from一般参数
In 参数表 of the element 供热/供冷区, the user ticked off 标准基本参数 - otherwise, the field is available only in the 自动 status, with no edition possibilities. 12. 系统构造板- selection in 参数表
绝热层选择
13. 绝热层选择
自动 The program selects 绝热层选择 with minimal resistance according to EN 1264: 1:2011 2:2013 3,4:2009 5:2008 for a given structural panel and upon the 另一侧的温度 value. 14. 绝热层选择 - 自动
手动 It is possible to choose 绝热层选择 from the catalogue or to define one's own by choosing particular insulation layers (up to 5 layers). 15. 绝热层选择 - 手动
盘管辐射构造断面图
The user may change the way in which the structure cross section drawing is presented.
16. 盘管辐射构造断面图
Structural and heating partition data editing
17. Structural and heating partition data
The program does not select elements among 围护结构定义 from the 建筑热负荷计算 scope, and they should be corrected manually.