查看和打印计算结果:修订间差异
跳转到导航
跳转到搜索
(创建页面,内容为“==Description== The article describes the presentation of project calculation results in tabular and graphic form in terms of: * viewing and handling diagnostic mes...”) |
|||
| 第7行: | 第7行: | ||
* preparing tabular part of calculation results for printing, | * preparing tabular part of calculation results for printing, | ||
* preparing graphic part of calculation results for printing. | * preparing graphic part of calculation results for printing. | ||
==Location in program== | |||
===Viewing and handling diagnostic messages=== | |||
* Viewing and handling diagnostic messages can be launched from the ''<IS_TS id=ErrorModuleTitle/>'' window.<br/>[[File:Diagnostics-location-3.png|900 px|left|thumb|1. ''<IS_TS id=ErrorModuleTitle/>'']]<br clear="all"/> | |||
===Viewing calculation results in tables=== | |||
* Viewing calculation results in tables can be launched from the ''<IS_TS id=ResultModuleTitle/>'' window.<br/>[[File:Results-location-2.png|900 px|left|thumb|2. ''<IS_TS id=ResultModuleTitle/>'']]<br clear="all"/> | |||
===Printing the tabular and graphic parts of the project=== | |||
* Printing of the tabular and graphic parts of the project can be launched from the ''<IS_TS id=Printouts/>'' window.<br/>[[File:Printuots-location-2.png|900 px|left|thumb|3. ''<IS_TS id=Printouts/>'']]<br clear="all"/> | |||
==Examples of use== | |||
===Viewing and handling diagnostic messages=== | |||
* Message levels: | |||
** ''<IS_TS id=cErrorStringPlural/>'' [[File:Diagnostics-errors-ikon.png|18 px|]] - messages of the highest importance. All errors that occur during project development must be eliminated, otherwise the results may not be complete. There are two types of errors: critical errors, which halt calculations, and errors that do not interrupt calculations, their occurrence, however, may lead to unreliable results. | |||
** ''<IS_TS id=cWarningStringPlural/>'' [[File:Diagnostics-warnings-ikon.png|18 px|]] - messages of lesser importance than errors. Warnings do not stop calculations or display of results. Warnings are usually associated with data or results that are presumably incorrect and should always be checked. | |||
** ''<IS_TS id=cHintStringPlural/>'' [[File:Diagnostics-hints-ikon.png|18 px|]] - messages that only remind or draw attention to some data or results. Like warnings, hints do not block further calculations or display of results. | |||
* Diagnostic window tabs.<br/> These group messages from a selected range of calculations and provide information on the levels of messages that have occurred during calculations of the selected range.<br/>[[File:Diagnostics-tabs.png|900 px|left|thumb|4. Diagnostic window tabs]]<br clear="all"/> | |||
* Message filtering.<br/> Enables turning off complete levels of messages. Very useful for systematizing the handling of diagnostic messages.<br/>{{#ev:youtube|1lqv4Cv-4yQ|900||||rel=0}} <br clear="all"/> | |||
* Message grouping for selected components.<br/> This function enables gathering all diagnostic messages that apply to a selected component in the project and eliminating them at once in a single data editing operation.<br/>{{#ev:youtube|HuKdw0XTBgc|900||||rel=0}} <br clear="all"/> | |||
* Selective marking of components to which a message applies.<br/> Marking of individual components may be effected by left double clicking the message or by selecting from a list of components to which a collective message applies.<br/>{{#ev:youtube|eYFgPP9s4-M|900||||rel=0}} <br clear="all"/> | |||
* Group marking of components to which a message applies.<br/> Marking of multiple components may be effected by left double clicking the message or by selecting the ''<IS_TS id=sZaznaczWszystkieElementyWKtorychWystapilTenBlad/>'' function in the menu.<br/>{{#ev:youtube|p37gdwAq7RM|900||||rel=0}} <br clear="all"/> | |||
* Extended information on diagnostic messages. | |||
** Diagnostic messages that require wider explanation in order to eliminate them may refer to the extended HelpSystem. It can be accessed by clicking the [[File:Diagnostics-hs.png|18 px|]] button at the end of the message line.<br/>{{#ev:youtube|MpDgczCeS44|900||||rel=0}} <br clear="all"/> | |||
** Selected diagnostic messages in the ''<IS_TS id=Field/>'' column indicate to which specific fields in the ''<IS_TS id=DataEditorTable/>'' or in dedicated editors the diagnosed values apply.<br/>[[File:Diagnostics-field.png|900 px|left|thumb|5. Extended information on diagnostic messages]]<br clear="all"/> | |||
===Presentation of calculation results of a project that has a Not Calculated status=== | |||
* The invalid or not calculated status of a project is indicated by a warning symbol displayed on the status bar.<br/>[[File:Status-bar-non-calc-results.png|900 px|left|thumb|6. Project not calculated - status bar]]<br clear="all"/> | |||
* Invalid or not calculated results are indicated by: | |||
** crossed out values in labels, | |||
** question marks in hints, | |||
** appropriate messages on invalid calculation results: | |||
*** ''<IS_TS id=CalculationResultsAreOutOfDate/>'' | |||
*** ''<IS_TS id=PrintoutsAreOutdate/>''<br/>[[File:Status-non-calc-results.png|900 px|left|thumb|7. Project not calculated]]<br clear="all"/> | |||
===Viewing calculation results as hints=== | |||
* The program enables convenient viewing of component data and calculation results in the form of hints. To display a hint with component data and results, position the mouse cursor over the component and wait for a moment. For some components, e.g. a radiator with integrated valve or a manifold with a manifold set, hints of differing content can be displayed depending on the place the cursor is positioned. When the cursor is positioned over a junction (point of connection of pipe-runs), the hint contains information on the manner of constructing the junction (selected and sized pipe fittings and accessories) using components available in catalogs.<br/>{{#ev:youtube|qr3KjtUUORI|900||||rel=0}} <br clear="all"/> | |||
===Viewing calculation results in tables=== | |||
* Tabular calculation results are presented in a tree structure divided into sections. The number and contents of a section corresponds to the scope(s) of the project and the result sought should be looked for in the appropriate section. Result viewing is facilitated by a number of display control functions: view single pages, view multiple pages, navigate using miniatures. Tables of results can have their headings hidden, and bills of materials can be displayed with additional graphical and descriptive information on the products.<br/>{{Info}} [[Using catalogs and catalogs data in the project]]<br/>{{#ev:youtube|MMpcfAYR0QA|900||||rel=0}} <br clear="all"/> | |||
===Preparing tabular part of calculation results for printing=== | |||
* It is possible to print: | |||
** a setup (composition) (predefined or user-defined) - from within the ''<IS_TS id=Printouts/>'' module.<br/>{{#ev:youtube|FSL_MmG2OTc|900||||rel=0}} <br clear="all"/> | |||
** a single table - from within the ''<IS_TS id=ResultModuleTitle/>'' module.<br/>The ''Print'' operation can be launched for the individual sections in the tree in the calculation results viewing window. | |||
===Preparing graphic part of calculation results for printing=== | |||
* ''<IS_TS id=InsertPageLayout/>''.<br/>{{Info}} [[Export / print results and drawings]] | |||
* ''<IS_TS id=Label/>''.<br/>{{#ev:youtube|9WYhDCxj8BI|900||||rel=0}} <br clear="all"/> | |||
* ''<IS_TS id=iNameTabelkaRozdzielacza/>''.<br/>{{#ev:youtube|lKSoDWGzGhw|900||||rel=0}} <br clear="all"/> | |||
* ''<IS_TS id=WezownicaCaption/>''.<br/>{{Info}} [[Appending drawings with radiant system loops|Appending drawings with radiant system loops]] | |||
* ''<IS_TS id=RysunekPrzekrojuKonstrukcji/>''.<br/>{{#ev:youtube|ijAsfcAUtXo|900||||rel=0}} <br clear="all"/> | |||
* ''<IS_TS id=iNameRamkaRysunkowa/>''.<br/>{{#ev:youtube|UJ5T5uaSARc|900||||rel=0}} <br clear="all"/> | |||
* ''<IS_TS id=iNameTabelkaProjektu/>''.<br/>{{#ev:youtube|zgtle5bVGB4|900||||rel=0}} <br clear="all"/> | |||
[[pl:Prezentacja wyników obliczeń]] | |||
[[Category:InstalSystem 5]] | |||
[[Category:FUNCTIONALITY]] | |||
2017年9月30日 (六) 10:39的版本
Description
The article describes the presentation of project calculation results in tabular and graphic form in terms of:
- viewing and handling diagnostic messages,
- viewing calculation results as hints,
- viewing calculation results in tables,
- preparing tabular part of calculation results for printing,
- preparing graphic part of calculation results for printing.
Location in program
Viewing and handling diagnostic messages
Viewing calculation results in tables
Printing the tabular and graphic parts of the project
- Printing of the tabular and graphic parts of the project can be launched from the 打印输出 window.

3. 打印输出
Examples of use
Viewing and handling diagnostic messages
- Message levels:
- 错误
- messages of the highest importance. All errors that occur during project development must be eliminated, otherwise the results may not be complete. There are two types of errors: critical errors, which halt calculations, and errors that do not interrupt calculations, their occurrence, however, may lead to unreliable results. - 警告
- messages of lesser importance than errors. Warnings do not stop calculations or display of results. Warnings are usually associated with data or results that are presumably incorrect and should always be checked. - 提示
- messages that only remind or draw attention to some data or results. Like warnings, hints do not block further calculations or display of results.
- 错误
- Diagnostic window tabs.
These group messages from a selected range of calculations and provide information on the levels of messages that have occurred during calculations of the selected range.
4. Diagnostic window tabs - Message filtering.
Enables turning off complete levels of messages. Very useful for systematizing the handling of diagnostic messages.
- Message grouping for selected components.
This function enables gathering all diagnostic messages that apply to a selected component in the project and eliminating them at once in a single data editing operation.
- Selective marking of components to which a message applies.
Marking of individual components may be effected by left double clicking the message or by selecting from a list of components to which a collective message applies.
- Group marking of components to which a message applies.
Marking of multiple components may be effected by left double clicking the message or by selecting the 标出所有发生错误的部件 function in the menu.
- Extended information on diagnostic messages.
- Diagnostic messages that require wider explanation in order to eliminate them may refer to the extended HelpSystem. It can be accessed by clicking the
button at the end of the message line.
- Selected diagnostic messages in the 说明 column indicate to which specific fields in the 参数表 or in dedicated editors the diagnosed values apply.

5. Extended information on diagnostic messages
- Diagnostic messages that require wider explanation in order to eliminate them may refer to the extended HelpSystem. It can be accessed by clicking the
Presentation of calculation results of a project that has a Not Calculated status
- The invalid or not calculated status of a project is indicated by a warning symbol displayed on the status bar.

6. Project not calculated - status bar - Invalid or not calculated results are indicated by:
Viewing calculation results as hints
- The program enables convenient viewing of component data and calculation results in the form of hints. To display a hint with component data and results, position the mouse cursor over the component and wait for a moment. For some components, e.g. a radiator with integrated valve or a manifold with a manifold set, hints of differing content can be displayed depending on the place the cursor is positioned. When the cursor is positioned over a junction (point of connection of pipe-runs), the hint contains information on the manner of constructing the junction (selected and sized pipe fittings and accessories) using components available in catalogs.
Viewing calculation results in tables
- Tabular calculation results are presented in a tree structure divided into sections. The number and contents of a section corresponds to the scope(s) of the project and the result sought should be looked for in the appropriate section. Result viewing is facilitated by a number of display control functions: view single pages, view multiple pages, navigate using miniatures. Tables of results can have their headings hidden, and bills of materials can be displayed with additional graphical and descriptive information on the products.
更多信息,见: Using catalogs and catalogs data in the project
Preparing tabular part of calculation results for printing
- It is possible to print:
- a setup (composition) (predefined or user-defined) - from within the 打印输出 module.
- a single table - from within the 结果 module.
The Print operation can be launched for the individual sections in the tree in the calculation results viewing window.
- a setup (composition) (predefined or user-defined) - from within the 打印输出 module.
Preparing graphic part of calculation results for printing
- 插入页面布局.
更多信息,见: Export / print results and drawings - 标签.
- 分集水器设置表.
- 辐射供暖供冷回路.
更多信息,见: Appending drawings with radiant system loops - 盘管辐射构造断面图.
- 图框.
- 标题栏.