如何删除: "对于卫生器具,标高差太大"
| 产品 | InstalSystem 5 |
| 文章类型 | TIP&TRICK |
| 版本的最新内容 | 2024-06-26 |
Problem description
The problem relates to the design of the 生活排水系统计算 and is indicated with the following diagnostic message:
- 对于卫生器具(%s),标高差太大(%s).
The 警告 is displayed when the value of the elevation drop between the ordinates of the 卫生器具 and the beginning of the next horizontal (near-horizontal) section of the branch or (if there is not such section) between the ordinates of the 卫生器具 and the end of the last section of the branch is bigger than the value of "Maximum drop (H)" specified in the Standard EN 12056-2:2000.

Note: According to the Standard for unventilated discharge branches the value of H should be less or equal 1m, for ventilated discharge branches - less or equal 3m.
Solution
This diagnostic message is not critical and has no influence on the further calculations of the installation. If you choose to remove it, this can be done in the following ways:
- Add local ventilation - 吸气阀:
- Reconfigure the geometry of the installation.