'''Base module''' | |||
* Introduced the ability to search elements in the Project browser based on a string of signs. | |||
* Allowed to insert dormers. | |||
====Articles in HelpSystem:==== | |||
* [[Designing heating systems with convective radiators]] | |||
* [[Designing of radiant heating installation on the basis of data from the Smart application]] | |||
* [[Heating/cooling zone]] | |||
* [[Using catalogs and catalogs data in the project]] | |||
===Version BETA 37 Rev. 0.0.B37=== | |||
====Modules:==== | |||
'''Base module''' | |||
* Improved efficiency of the program in handling with complex projects, time of files upload and regeneration of the 3D view. | |||
'''Radiator sizing''' | |||
* Added the ability to search of radiators and valves placed on the radiators in the search window of elements in the project. | |||
'''Heat loss (thermal load)''' | |||
* Introduced heat loss (thermal load) module in accordance with standard EN 12831. | |||
====Articles in HelpSystem:==== | |||
* [[Preparation of building structure]] (actualized) | |||
* [[Smart application - Quick selection of system components]] (actualized) | |||
===Version BETA 35 Rev. 0.0.B35=== | |||
====Modules:==== | |||
'''Base module''' | |||
* Raising the ergonomics of editing the roof by multiedit few vertices at the same time. | |||
* Merge and trim functions identify the premises in one operation. | |||
* Introduced new physical elements - arched Windows and doors. | |||
* Introduced new physical element - Opening in slab. | |||
* Improved support for facilities construction if the hole in the roof. | |||
* Introduced new feature - Building contour. | |||
* Introduced the interpretation of walls based on stroke building. | |||
* Introduced a new feature - Partitions generator. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] (actualized) | |||
* [[General data]] | |||
* [[Import files]] (actualized) | |||
* [[Manifold and accessories]] (actualized) | |||
* [[Preparation of building structure]] | |||
===Version BETA 34 Rev. 0.0.B34=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved import files created in InstalSystem 4 for automatic deletion of elements that are not supported in InstalSystem 5. | |||
* Improved ''Wall'' connection. | |||
* Integrated a full range of ''Construction'' processing operations. | |||
'''Radiator sizing''' | |||
* Expanded radiator sizing in ''Addition for thermostat'' and ''Addition for casing/chanel''. | |||
* Expanded operations on the elements ''Radiators'' about the possibility of ''Flip horizontal''. | |||
====Articles in HelpSystem:==== | |||
* [[Design of radiant heating/radiant cooling installation]] | |||
* [[Designing radiant (ceiling, wall) panel heating/cooling systems]] | |||
* [[Designing radiant heating systems with pipe-runs as distribution system]] | |||
* [[Radiant steel ceiling panels]] | |||
===Version BETA 33 Rev. 0.0.B33=== | |||
====Modules:==== | |||
'''Radiant heating - loop systems''' | |||
* Improved the data propagation from ''Room'' elements created with walls to the ''Heating/Cooling Wall Zone'' elements. | |||
'''Radiator sizing''' | |||
* Improved the data propagation from ''Room'' elements created with walls to the ''Radiator'' elements. | |||
===Version BETA 32 Rev. 0.0.B32=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced the ability of creating rooms due to other building structure's elements inserted in the project. | |||
* Introduced the ability of dividing roof into parts and added new functionality which allows to change ordinates of individual points at the roof's outline to model its real surface. | |||
* Introduced new physical element - roof window. | |||
* Introduced new physical element - recess. | |||
* Improved evaluating the location of the elements above the plane of the floor. | |||
* Increased the ergonomy of label editor. | |||
'''Radiator sizing''' | |||
* Introduced radiator sizing in basic scope. This functionality will be completed and developed in the next beta versions. | |||
====Articles in HelpSystem:==== | |||
* [[Design of radiant heating floor and wall installation]] | |||
Base module, including InstalSystem Manager | ===Version BETA 31 Rev. 0.0.B31=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Introduced a new conception for wall element and the functionality of connecting walls. | |||
* Indroduced new physical element - the slab. | |||
* Indroduced new physical element - the roof. | |||
* Expanded function "Shadow of a storey" for possibility to declare shadows displayed for all stories below. | |||
'''Radiant heating - panel systems''' | |||
* Introduced possibility of calculating thermal output of ceiling/wall panels according to EN 1264 standard. | |||
Articles in HelpSystem:[ | ====Articles in HelpSystem:==== | ||
* [[Release notes InstalSystem Smart5]] | |||
Version BETA | ===Version BETA 30 Rev. 0.0.B30=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Allowed to control the content of diagnostic messages using the checkbox "Messages for selected components" on the list of filters in the diagnostics window. | |||
* Introduced the possibility to handle by the distribution system mail domains with the sign "-". | |||
'''Radiant heating - panel systems''' | |||
* Taken into account results for panels in the radiant heating general results. | |||
* Introduced the presentation of panels connection points on 3D view. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] (actualized) | |||
* [[How to eliminate problems with the diagnostic message: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually"]] | |||
* [[Smart application - Quick selection of system components]] | |||
===Version BETA 29 Rev. 16.5.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Allowed handling of mail domains containing sign "-" by the licence distribution system. | |||
* Improved stability of the program during pasting complex installations. | |||
* Introduced the ability to display the storeys shadow above and below on 2D view. | |||
* For each element with snapping possibility added the ability to set in the AUTO mode a parameter which predetermine distance from the edge of another inserted element. | |||
'''Radiant heating - loop systems''' | |||
* Corrected a bug related to the manual connecting RHC loop directly to the manifold (without pipe-runs). | |||
'''Radiant heating - panel systems''' | |||
* Allowed the presentation of data in the printout of 'Manifold table' for panel systems installation. | |||
'''Radiant heating - dry systems''' | |||
* Introduced dry system to the neutral catalogue of radiant heating systems. | |||
====Articles in HelpSystem:==== | |||
* [[Installation, activation and update InstalSystem 5 package]] | |||
* [[Manifold and accessories]] | |||
* [[Project and application management]] | |||
===Version BETA 28 Rev. 16.4.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved the automatic snapping of pipe-runs for the ORTO mode. | |||
* Improved the function of rooms interpretation for files imported from '''[[InstalSystem 4]]''' package. | |||
* Introduced the ability to insert into the project construction elements: ''Wall'', ''Window'', ''Door'', ''Opening in wall''. | |||
'''Radiant heating - panel systems''' | |||
* Introduced the possibility to insert into the project element ''Ceiling false panel'' (panel with no connection). | |||
* Added the cooling result card for panel installation: ''General results cooling''. | |||
* Included elements: ''Wall panel'' and ''Ceiling panel'' in results card: ''General results heating''. | |||
Modules: | ===Version BETA 27 Rev. 16.3.1=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved function 'automatically connect terminal units'. | |||
* Made available the ability to configure the buttons to select a group of elements (SHIFT and CTRL). | |||
* Introduced possibility of selecting 'None' in the climatic data in case of lack of apropriate climatic data catalogue in the program. | |||
* Added the function of the graphic presentation of the route of flow from a given receiver to the source. | |||
* Added the function of the graphic presentation of routes flow from the source (manifold, source) to all receivers, which it supplies. | |||
'''Radiant heating - dry systems''' | |||
* Introduced handling underfloor panels which lead the pipes in dry systems of radiant heating. | |||
===Version BETA 26 Rev. 16.2.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved saving files in a network location. | |||
* Introduced the possibility to choose the source for which you want to appear the critical circuit. | |||
===Version BETA 25 Rev. 16.1.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added function that allows automatically connect terminal units. | |||
* Added possibility of quick creating rectangular room with sides parallel to the X, Y by drawing diagonal of the room. | |||
* The problem with sending Problem Report Form is eliminated. | |||
'''Radiant heating - panel systems''' | |||
* Added function that allows connect panels in series. | |||
* Introduced the possibility to design heating/cooling installations using ceiling/wall panels (including radiant steel ceiling panels).<br/>''Attention! Required upgrade to the configuration with the new module (InstalSystem Manager - tab "Upgrade"). | |||
====Articles in HelpSystem:==== | |||
* [[Connecting storeys with the "Stack" element]] | |||
* [[View navigation in the graphical editor]] | |||
* [[Combine base files]] | |||
===Version BETA 24 Rev. 15.12.1=== | |||
''Warning! For this version of the program the reinstallation is necessary.'' | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Improved stability and quality of the program. | |||
'''Radiant heating - loop systems''' | |||
* Added a message about the lack of possibility for editing automatically generated pipe feeds/RHC loops. | |||
* Standarized the content of data table for heating/cooling zones at various ranges of editing. | |||
* Introduced permanent visibility of the field ''Pipe laying pattern'' in the data table for heating/cooling zones. | |||
* Fixed an error that occurs while connecting pipe feeds route to the heating/cooling zone. | |||
====Articles in HelpSystem:==== | |||
* [[Export / print results and drawings]] | |||
* [[Software configuration]] (actualized) | |||
Base module, including InstalSystem Manager | ===Version BETA 23 Rev. 15.11.1=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Fixed the problem with sending the Problem report form. | |||
* Added icons for the .isproj files displayed in the InstalSystem Manager and in the Windows Explorer's window. | |||
* The scope of the displayed catalogues in the general data has been adapted to the available project scope for the package. | |||
Radiant heating - loop systems | '''Radiant heating - loop systems''' | ||
* Changed the designation of nodes in the grid which supports the manual drawing of the loop. | |||
* Added message box indicating the inability to remove the RHC loop. | |||
'''Heating network with balancing''' | |||
* Fixed the automatic sizing of manifolds' cabinets. | |||
* Improved the propagation of the default data for manifold cabinet. | |||
====Articles in HelpSystem:==== | |||
* [[Editing pipe feeds in a radiant system]] | |||
* [[How to make the program run faster]] | |||
* [[Installation with ceiling heating and cooling system in commercial building]] | |||
* [[Search components in the project]] | |||
===Version BETA 22 Rev. 15.10.1=== | |||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay. | |||
* Improved ORTO and AUTO modes. | |||
* Fixed the problem with sending error report form after crash of the program. | |||
* Improved overall stability and quality of the program by eliminating the reported errors. | |||
====Articles in HelpSystem:==== | |||
* [[Import files]] | |||
* [[Appending drawings with radiant system loops]] | |||
Version BETA | ===Version BETA 21 Rev. 15.9.2=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Modified the way of importing base drawing files. | |||
* Added a ''Select components in rectangle'' function under the left mouse button. | |||
* Improved acting of ''ORTO'' mode when moving objects. | |||
* Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower. | |||
'''Radiant heating - loop systems''' | |||
* Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold. | |||
* Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects. | |||
'''Heating network with balancing''' | |||
* Added the possibility to use multi-circuit heating floor zone. | |||
* Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold. | |||
* Added the possibility to supply multi-circuit heating floor zone from several manifolds. | |||
* Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold. | |||
====Articles in HelpSystem:==== | |||
* [[Calculation of cooling capacity for radiant systems (floor, wall or ceiling)]] | |||
* [[How to calculate a file using a package configuration other than the one under which the file was created]] | |||
* [[Installation with underfloor and wall radiant heating system in single family building]] | |||
Version BETA | ===Version BETA 16.1 Rev. 15.5.17=== | ||
====Modules:==== | |||
'''Base module, including InstalSystem Manager''' | |||
* Added new tool to search and select items in the project. | |||
* Improved the import and export of bases. | |||
* Introduced the control of print range which based on the edition range and the elements' styles. | |||
* Introduced the possibility to highlight and select project's elements to which messages on the diagnostic list referred to. | |||
* Added the possibility to highlight on the worksheet elements forming the circuit of specified receptor from this worksheet. | |||
'''Radiant heating - loop systems''' | |||
* Improved the functionality of pipe feed automatic generation. | |||
====Articles in HelpSystem:==== | |||
* [[Software configuration]] | |||
Radiant heating - | ===Version BETA 15.1 Rev. 15.4.21=== | ||
====Initial scope of modules:==== | |||
* '''Base module, including InstalSystem Manager''' | |||
* '''Radiant heating - loop systems''' | |||
* '''Cooling mode for radiant systems''' | |||
* '''Heating network with balancing''' | |||
* '''BIM Interface (gbXML)''' | |||
====Initial state of articles in HelpSystem==== | |||
* [[Technical specifications of InstalSystem 5 package]] | |||
* [[Introduction to the work with the package InstalSystem 5]] | |||
[[Category:InstalSystem 5]] | |||
[[Category:PRODUCT INFORMATION]] | |||
[[it:Informazioni sulle pubblicazioni InstalSystem 5]] | |||
[[pl:Informacje o publikacjach InstalSystem 5]] | |||
[[lt:InstalSystem 5 Pastabos apie versiją]] | |||
[[bg:Информация относно промени в InstalSystem 5]] | |||
2017年2月26日 (日) 03:22的版本
Information about changes
Version BETA Rev. 2.0.B1
Modules:
Base module
- Introduced the ability to search elements in the Project browser based on a string of signs.
- Allowed to insert dormers.
Articles in HelpSystem:
- Designing heating systems with convective radiators
- Designing of radiant heating installation on the basis of data from the Smart application
- Heating/cooling zone
- Using catalogs and catalogs data in the project
Version BETA 37 Rev. 0.0.B37
Modules:
Base module
- Improved efficiency of the program in handling with complex projects, time of files upload and regeneration of the 3D view.
Radiator sizing
- Added the ability to search of radiators and valves placed on the radiators in the search window of elements in the project.
Heat loss (thermal load)
- Introduced heat loss (thermal load) module in accordance with standard EN 12831.
Articles in HelpSystem:
- Preparation of building structure (actualized)
- Smart application - Quick selection of system components (actualized)
Version BETA 35 Rev. 0.0.B35
Modules:
Base module
- Raising the ergonomics of editing the roof by multiedit few vertices at the same time.
- Merge and trim functions identify the premises in one operation.
- Introduced new physical elements - arched Windows and doors.
- Introduced new physical element - Opening in slab.
- Improved support for facilities construction if the hole in the roof.
- Introduced new feature - Building contour.
- Introduced the interpretation of walls based on stroke building.
- Introduced a new feature - Partitions generator.
Articles in HelpSystem:
- Editing pipe feeds in a radiant system (actualized)
- General data
- Import files (actualized)
- Manifold and accessories (actualized)
- Preparation of building structure
Version BETA 34 Rev. 0.0.B34
Modules:
Base module, including InstalSystem Manager
- Improved import files created in InstalSystem 4 for automatic deletion of elements that are not supported in InstalSystem 5.
- Improved Wall connection.
- Integrated a full range of Construction processing operations.
Radiator sizing
- Expanded radiator sizing in Addition for thermostat and Addition for casing/chanel.
- Expanded operations on the elements Radiators about the possibility of Flip horizontal.
Articles in HelpSystem:
- Design of radiant heating/radiant cooling installation
- Designing radiant (ceiling, wall) panel heating/cooling systems
- Designing radiant heating systems with pipe-runs as distribution system
- Radiant steel ceiling panels
Version BETA 33 Rev. 0.0.B33
Modules:
Radiant heating - loop systems
- Improved the data propagation from Room elements created with walls to the Heating/Cooling Wall Zone elements.
Radiator sizing
- Improved the data propagation from Room elements created with walls to the Radiator elements.
Version BETA 32 Rev. 0.0.B32
Modules:
Base module, including InstalSystem Manager
- Introduced the ability of creating rooms due to other building structure's elements inserted in the project.
- Introduced the ability of dividing roof into parts and added new functionality which allows to change ordinates of individual points at the roof's outline to model its real surface.
- Introduced new physical element - roof window.
- Introduced new physical element - recess.
- Improved evaluating the location of the elements above the plane of the floor.
- Increased the ergonomy of label editor.
Radiator sizing
- Introduced radiator sizing in basic scope. This functionality will be completed and developed in the next beta versions.
Articles in HelpSystem:
Version BETA 31 Rev. 0.0.B31
Modules:
Base module, including InstalSystem Manager
- Introduced a new conception for wall element and the functionality of connecting walls.
- Indroduced new physical element - the slab.
- Indroduced new physical element - the roof.
- Expanded function "Shadow of a storey" for possibility to declare shadows displayed for all stories below.
Radiant heating - panel systems
- Introduced possibility of calculating thermal output of ceiling/wall panels according to EN 1264 standard.
Articles in HelpSystem:
Version BETA 30 Rev. 0.0.B30
Modules:
Base module, including InstalSystem Manager
- Allowed to control the content of diagnostic messages using the checkbox "Messages for selected components" on the list of filters in the diagnostics window.
- Introduced the possibility to handle by the distribution system mail domains with the sign "-".
Radiant heating - panel systems
- Taken into account results for panels in the radiant heating general results.
- Introduced the presentation of panels connection points on 3D view.
Articles in HelpSystem:
- Editing pipe feeds in a radiant system (actualized)
- How to eliminate problems with the diagnostic message: "Automatic arrangement of pipe feeds not possible - change pipe feeds route or H/C Zone parameters or arrange pipe feeds manually"
- Smart application - Quick selection of system components
Version BETA 29 Rev. 16.5.1
Modules:
Base module, including InstalSystem Manager
- Allowed handling of mail domains containing sign "-" by the licence distribution system.
- Improved stability of the program during pasting complex installations.
- Introduced the ability to display the storeys shadow above and below on 2D view.
- For each element with snapping possibility added the ability to set in the AUTO mode a parameter which predetermine distance from the edge of another inserted element.
Radiant heating - loop systems
- Corrected a bug related to the manual connecting RHC loop directly to the manifold (without pipe-runs).
Radiant heating - panel systems
- Allowed the presentation of data in the printout of 'Manifold table' for panel systems installation.
Radiant heating - dry systems
- Introduced dry system to the neutral catalogue of radiant heating systems.
Articles in HelpSystem:
- Installation, activation and update InstalSystem 5 package
- Manifold and accessories
- Project and application management
Version BETA 28 Rev. 16.4.1
Modules:
Base module, including InstalSystem Manager
- Improved the automatic snapping of pipe-runs for the ORTO mode.
- Improved the function of rooms interpretation for files imported from InstalSystem 4 package.
- Introduced the ability to insert into the project construction elements: Wall, Window, Door, Opening in wall.
Radiant heating - panel systems
- Introduced the possibility to insert into the project element Ceiling false panel (panel with no connection).
- Added the cooling result card for panel installation: General results cooling.
- Included elements: Wall panel and Ceiling panel in results card: General results heating.
Version BETA 27 Rev. 16.3.1
Modules:
Base module, including InstalSystem Manager
- Improved function 'automatically connect terminal units'.
- Made available the ability to configure the buttons to select a group of elements (SHIFT and CTRL).
- Introduced possibility of selecting 'None' in the climatic data in case of lack of apropriate climatic data catalogue in the program.
- Added the function of the graphic presentation of the route of flow from a given receiver to the source.
- Added the function of the graphic presentation of routes flow from the source (manifold, source) to all receivers, which it supplies.
Radiant heating - dry systems
- Introduced handling underfloor panels which lead the pipes in dry systems of radiant heating.
Version BETA 26 Rev. 16.2.1
Modules:
Base module, including InstalSystem Manager
- Improved saving files in a network location.
- Introduced the possibility to choose the source for which you want to appear the critical circuit.
Version BETA 25 Rev. 16.1.1
Modules:
Base module, including InstalSystem Manager
- Added function that allows automatically connect terminal units.
- Added possibility of quick creating rectangular room with sides parallel to the X, Y by drawing diagonal of the room.
- The problem with sending Problem Report Form is eliminated.
Radiant heating - panel systems
- Added function that allows connect panels in series.
- Introduced the possibility to design heating/cooling installations using ceiling/wall panels (including radiant steel ceiling panels).
Attention! Required upgrade to the configuration with the new module (InstalSystem Manager - tab "Upgrade").
Articles in HelpSystem:
- Connecting storeys with the "Stack" element
- View navigation in the graphical editor
- Combine base files
Version BETA 24 Rev. 15.12.1
Warning! For this version of the program the reinstallation is necessary.
Modules:
Base module, including InstalSystem Manager
- Improved stability and quality of the program.
Radiant heating - loop systems
- Added a message about the lack of possibility for editing automatically generated pipe feeds/RHC loops.
- Standarized the content of data table for heating/cooling zones at various ranges of editing.
- Introduced permanent visibility of the field Pipe laying pattern in the data table for heating/cooling zones.
- Fixed an error that occurs while connecting pipe feeds route to the heating/cooling zone.
Articles in HelpSystem:
Version BETA 23 Rev. 15.11.1
Modules:
Base module, including InstalSystem Manager
- Fixed the problem with sending the Problem report form.
- Added icons for the .isproj files displayed in the InstalSystem Manager and in the Windows Explorer's window.
- The scope of the displayed catalogues in the general data has been adapted to the available project scope for the package.
Radiant heating - loop systems
- Changed the designation of nodes in the grid which supports the manual drawing of the loop.
- Added message box indicating the inability to remove the RHC loop.
Heating network with balancing
- Fixed the automatic sizing of manifolds' cabinets.
- Improved the propagation of the default data for manifold cabinet.
Articles in HelpSystem:
- Editing pipe feeds in a radiant system
- How to make the program run faster
- Installation with ceiling heating and cooling system in commercial building
- Search components in the project
Version BETA 22 Rev. 15.10.1
Modules:
Base module, including InstalSystem Manager
- Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay.
- Improved ORTO and AUTO modes.
- Fixed the problem with sending error report form after crash of the program.
- Improved overall stability and quality of the program by eliminating the reported errors.
Articles in HelpSystem:
Version BETA 21 Rev. 15.9.2
Modules:
Base module, including InstalSystem Manager
- Modified the way of importing base drawing files.
- Added a Select components in rectangle function under the left mouse button.
- Improved acting of ORTO mode when moving objects.
- Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower.
Radiant heating - loop systems
- Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold.
- Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects.
Heating network with balancing
- Added the possibility to use multi-circuit heating floor zone.
- Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold.
- Added the possibility to supply multi-circuit heating floor zone from several manifolds.
- Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold.
Articles in HelpSystem:
- Calculation of cooling capacity for radiant systems (floor, wall or ceiling)
- How to calculate a file using a package configuration other than the one under which the file was created
- Installation with underfloor and wall radiant heating system in single family building
Version BETA 16.1 Rev. 15.5.17
Modules:
Base module, including InstalSystem Manager
- Added new tool to search and select items in the project.
- Improved the import and export of bases.
- Introduced the control of print range which based on the edition range and the elements' styles.
- Introduced the possibility to highlight and select project's elements to which messages on the diagnostic list referred to.
- Added the possibility to highlight on the worksheet elements forming the circuit of specified receptor from this worksheet.
Radiant heating - loop systems
- Improved the functionality of pipe feed automatic generation.
Articles in HelpSystem:
Version BETA 15.1 Rev. 15.4.21
Initial scope of modules:
- Base module, including InstalSystem Manager
- Radiant heating - loop systems
- Cooling mode for radiant systems
- Heating network with balancing
- BIM Interface (gbXML)